Short, plain-English definitions of 99 terms used in aluminium glazing, curtain walling, rainscreen cladding, fire rated glazing and the Building Regulations in England, from mullions and U-values to EI30 and Gateway 2. The definitions draw on the Approved Documents, legislation, British Standards and manufacturers' published data, and each links to the guide or product page that covers it in depth.
Curtain walling and façades
Back to topCurtain walling
Curtain walling is a non-loadbearing external wall, usually an aluminium frame filled with glass and insulated panels, that hangs off the edges of a building's floor slabs. It carries its own weight and the wind load back to the structure but supports no floors or roof, and its UK product standard is BS EN 13830.
Stick system
A stick system is curtain walling assembled on the building piece by piece: mullions are fixed to the slab edges, transoms are fixed between them, and the glass and infill panels are then fitted and sealed. It suits low- and mid-rise buildings, irregular elevations and smaller areas.
Unitised façade
A unitised façade is curtain walling made of large panels, usually one storey high and one grid module wide, that are glazed and sealed in a factory, lifted onto brackets at each floor and interlocked with the panels around them. Because most of the work is done off site, it goes up faster than a stick system and is common on tall and programme-critical buildings.
Semi-unitised curtain walling
Semi-unitised curtain walling is a mix of stick and unitised construction: the mullions and transoms are fixed on site, then frames or cassettes glazed in the factory are fitted into them. It moves some glazing off site without the full engineering of a unitised wall.
Mullion
A mullion is a vertical framing member that divides a window, screen or curtain wall. In curtain walling the mullions usually span from floor to floor and carry the weight and wind load of the wall back to brackets at the slab edges.
Transom
A transom is a horizontal framing member across a window, door frame, screen or curtain wall. In curtain walling the transoms run between the mullions and carry the weight of the glass and infill panels into them.
Spandrel panel
A spandrel panel is an opaque, insulated infill panel in a curtain wall where it passes floor slabs, ceiling voids and structure. On a relevant building in England, Approved Document B says spandrel and infill panels must meet the A2-s1, d0 or A1 rule for external walls.
Capped curtain walling
Capped curtain walling holds the glass with an aluminium pressure plate screwed to the mullions and transoms, which clamps it between gaskets, and a snap-on cover cap that hides the screws and gives the visible grid. It is a common and usually economical way to hold glass in a curtain wall.
Structural glazing
Structural glazing is glazing in which the glass is bonded to its supporting frame with structural silicone instead of being held by an external pressure plate, cap or bead, so the outside shows only glass and narrow silicone joints. The silicone carries the wind load to the frame, while the weight of the glass is usually taken by mechanical supports.
Window wall
A window wall is a run of glazing set between the floor slabs or into openings, so the slab edges are seen or clad separately. Curtain walling, by contrast, runs continuously past the slab edges and hangs in front of them.
CWCT
CWCT, the Centre for Window and Cladding Technology, is a UK membership organisation founded in 1989 and based in Bath that publishes standards and guidance on building envelopes and glazing. Its Standard for systemised building envelopes is widely referred to in UK curtain walling specifications for performance classes and laboratory testing.
Drained and ventilated frame
A drained and ventilated frame collects any water that gets past the outer seal of a window, door or curtain wall and drains it back to the outside through slots or channels. It is what lets the system stay watertight on exposed elevations instead of relying on a single outer seal.
Slab-edge fire stopping
Slab-edge fire stopping is the seal that closes the gap between each floor slab and the back of a curtain wall or external wall, so fire and smoke cannot pass from floor to floor behind the façade. Approved Document B asks for fire resistance to be maintained where a compartment floor or wall meets an external wall.
Cavity barrier
A cavity barrier is a construction inside a cavity that closes it to stop smoke or flame getting in, or restricts the movement of smoke or flame within it. In rainscreen cladding they close the ventilated cavity at its edges, around openings and at compartment floors and walls, as Approved Document B sets out.
Rainscreen cladding
Rainscreen cladding is an external wall system with two skins: outer panels that shed most of the rain, and an insulated, airtight backing wall, separated by a ventilated cavity. Water that gets past the panel joints drains down the cavity and out at the base, so the wall behind stays dry.
Cassette panel
A cassette panel is a rainscreen panel, usually aluminium, whose edges are folded back into a shallow tray that hooks or fixes onto rails behind it, so the fixings are hidden and the joints read as crisp shadow gaps. Cassettes can usually be removed one at a time, and they are a common form of flat aluminium rainscreen.
Brise soleil
Brise soleil, French for "sun breaker", is external solar shading: fixed or adjustable blades, fins or louvres mounted outside the glazing that stop high sun before it reaches the glass. It cuts heat gain and glare while keeping daylight and views.
Louvre
A louvre is a row of angled blades held in a frame that lets air, light or both pass while keeping out rain, direct sun or views. Weather louvres ventilate plant rooms, solar shading louvres cut heat gain on glazing, and screening louvres hide plant.
Free area
Free area is the open area of a louvre that air can actually pass through, usually given as a percentage of the louvre face. Rain defence is classified separately under BS EN 13030, from class A (most effective) to D.
Façade fin
A façade fin is a deep blade, usually aluminium, fixed at right angles to the glass, vertically or horizontally, to shade the glazing and give the elevation rhythm. Vertical fins block low east and west sun; horizontal fins block high summer sun on south-facing walls.
Fire performance
Back to topFire resistance
Fire resistance is the ability of an element such as a wall, door or glazed screen to keep doing its job in a fire for a stated time, measured in a standard furnace test. Under BS EN 13501-2 it is classified by the criteria met, such as integrity (E), insulation (I) and radiation (W), followed by the minutes, as in EI 60.
Integrity (E)
Integrity, shown by the letter E, is the ability of a fire-resisting element to stop flames and hot gases passing through it for the stated minutes. An E30 door or screen keeps its integrity for 30 minutes but can get hot on the protected side.
Insulation (I)
Insulation, shown by the letter I, means the protected face of a fire-resisting element stays below a set temperature rise as well as keeping its integrity. It is what lets people pass close to EI glass or doors during a fire; EI1 and EI2 show which of two definitions of insulation was used.
Radiation (EW)
EW is a fire resistance class for integrity with a limit on the heat radiated from the protected face, measured as radiation rather than surface temperature. It sits between E and EI; door classes are EW20, EW30 and EW60.
EI30 and EI60
EI30 and EI60 are fire resistance classes meaning the element kept both its integrity and its insulation for 30 or 60 minutes in a standard fire test. The period each wall, door or screen needs is set by the fire strategy, using the guidance in Approved Document B.
FD30
FD30 is the British Standard rating for a fire door that kept its integrity for 30 minutes in a BS 476-22 fire test; FD30S also restricts cold smoke. The European class for the same criterion is E30 (or E30 Sa), but it comes from a different test, so one cannot be assumed from the other.
Sa (smoke control)
Sa is the classification for a doorset that restricts smoke leakage at ambient temperature (cold smoke), tested to BS EN 1634-3. Approved Document B asks for it on doors to protected stairs, lobbies and corridors, as in E30 Sa.
Fire doorset
A fire doorset is a door or shutter that, together with its frame and hardware as installed, is intended to resist the spread of fire and smoke when closed. The rating only applies to the complete assembly that was tested or assessed, including the glass, seals and hinges.
Fire-resistant glass
Fire-resistant glass is glass tested to hold back fire for a stated time when glazed in a specific frame with its seals and fixings. Non-insulating types give E and some EW ratings; insulating types with intumescent interlayers or gel give EI ratings.
Compartment
A fire compartment is a building, or part of one, built to stop fire spreading to or from another part of the same building or an adjoining building. Compartment walls and floors are the fire-resisting walls and floors that separate one compartment from another, and Approved Document B Table C1 sets the rating doors in them need.
Fire strategy
A fire strategy is the design document that sets out how a building meets fire safety requirements, covering means of escape, compartmentation, fire spread inside and outside, and fire service access. It sets the fire resistance class each door, screen and façade element needs; for a higher-risk building it forms the fire and emergency file sent to the Building Safety Regulator.
Reaction to fire
Reaction to fire describes how much a material itself contributes to a fire: how readily it ignites and how much heat, smoke and burning droplets it gives off. It is classified under BS EN 13501-1 from A1, the best, down to F, with smoke sub-classes s1 to s3 and droplet sub-classes d0 to d2, and it is a different property from fire resistance.
A1 and A2-s1, d0
A1 and A2-s1, d0 are the two highest reaction-to-fire classes under BS EN 13501-1; in A2-s1, d0, s1 is the lowest smoke production class and d0 means no flaming droplets. In England, regulation 7(2) requires materials that become part of the external wall of a relevant building to meet one of them, with listed exemptions such as window frames, glass and seals.
BS 476
BS 476 is the older British Standard series of fire tests; part 22 gives the FD ratings for fire doors. From 2 September 2029, Approved Document B in England removes the BS 476 fire resistance classes and gives European classes under BS EN 13501-2 only.
Regulations and approvals
Back to topApproved Documents
Approved Documents are guidance approved by the Secretary of State on how to meet the requirements of the Building Regulations 2010 in England, one for each technical part, such as Approved Document B for fire safety. They set out one way to comply, not the only way; another approach should be agreed with the building control body early.
Approved Document B (Part B)
Approved Document B is the guidance on fire safety in England, in two volumes: Volume 1 for dwellings and Volume 2 for buildings other than dwellings. It covers means of escape, fire spread inside and outside the building, fire doors and access for the fire service.
Approved Document K (Part K)
Approved Document K is the guidance on protection from falling, collision and impact in England, covering stairs, guarding, and safety glass in critical locations. The current edition is from 2013, and Part K is under review by the Building Safety Regulator.
Approved Document L (Part L)
Approved Document L is the guidance on energy efficiency in England, setting maximum U-values for windows, doors, rooflights and curtain walling and the energy targets for new buildings. The 2026 edition applies from 24 March 2027, or 24 September 2027 for higher-risk building work.
Approved Document M (Part M)
Approved Document M is the guidance on access to and use of buildings in England, in two volumes: Volume 1 for dwellings and Volume 2 for other buildings. For doors in buildings other than dwellings it covers clear opening widths, opening forces, thresholds and vision panels.
Approved Document Q (Part Q)
Approved Document Q is the guidance on security in new dwellings in England: easily accessible doors and windows must resist physical attack by a burglar. It applies only to new homes, and doorsets and windows meeting PAS 24 are the usual way to show compliance.
Building control body
A building control body checks that building work meets the Building Regulations and signs it off. In England it is either the local authority or a registered building control approver, and for higher-risk buildings it is the Building Safety Regulator.
Competent person scheme
A competent person scheme is a government-authorised scheme whose registered installers can self-certify that certain building work, such as replacement windows and doors, meets the Building Regulations without a building control application. FENSA and CERTASS are examples for windows and doors.
Controlled fitting
A controlled fitting is a window, rooflight, roof window or door whose installation counts as building work and must meet the Building Regulations, such as a replacement external window or door, frame included. Under Approved Document L, replacing only the glass, or a window or door in its existing frame, is not providing a controlled fitting.
Building Safety Act 2022
The Building Safety Act 2022 is the law, passed after the Grenfell Tower fire, that makes provision about the safety of people in or about buildings and the standard of buildings. It set up the Building Safety Regulator and a stricter approval regime for higher-risk buildings, and led to dutyholder and competence duties for everyone who commissions, designs or builds.
Building Safety Regulator (BSR)
The Building Safety Regulator is the body that oversees building safety in England and is the building control authority for higher-risk buildings. It approves the design before work starts and issues the completion certificate at the end.
Higher-risk building
During design and construction in England, a higher-risk building is one at least 18 metres high or with at least seven storeys that contains at least two residential units, or is a care home or hospital meeting the same height test. Building work on it needs approval from the Building Safety Regulator before it starts.
Gateway 2
Gateway 2 is the name used for the point at which the Building Safety Regulator must give building control approval for work on a higher-risk building before construction can start. Unless an extension is agreed, the regulator takes up to 12 weeks to assess a new higher-risk building and up to 8 weeks for work to an existing one.
Relevant building
A relevant building, under regulation 7(4) of the Building Regulations 2010, has a storey at least 18 metres above ground level (ignoring roof-top plant) and contains one or more dwellings, an institution or a room for residential purposes. Materials in its external walls must be class A2-s1, d0 or A1, with listed exemptions.
Energy and U-values
Back to topU-value
A U-value is the rate of heat loss through a building element, in watts per square metre for each degree of temperature difference between inside and outside (W/m²K); the lower the number, the less heat is lost. For a window or door, Approved Document L limits the U-value of the whole unit, glass and frame together.
Uw (whole-window U-value)
Uw is the U-value of a whole window, combining the glass (Ug), the frame (Uf) and the edge of the glass unit, calculated to BS EN ISO 10077-1 and 10077-2 or measured in a hot-box test. It is the figure Part L limits, and it varies with the window size and layout; Ud is the same figure for a door.
Ug (centre-pane U-value)
Ug is the U-value of the glass alone, measured in the centre of the pane away from the frame and spacer, and calculated to BS EN 673. It is usually lower than the whole-window Uw, because frames and glass edges lose more heat, so a centre-pane figure should not be compared with a Part L limit for the whole window.
Ucw (curtain wall U-value)
Ucw is the whole-system U-value of a curtain wall, combining the frame, the glass and any spandrel panels across the elevation. Approved Document L sets a limit of 1.6 W/m²K for curtain walling in buildings other than homes and in new homes (1.4 W/m²K in an existing home), and the actual figure depends on the ratio of glass to opaque panels.
Window Energy Rating (WER)
A Window Energy Rating is an energy label, such as the one issued by BFRC on a scale from A++ to E, that rates a whole window on its heat loss, solar gain and air leakage together. In an existing home in England, band B or better is an alternative to the 1.4 W/m²K U-value limit in Approved Document L.
Doorset Energy Rating (DSER)
A Doorset Energy Rating is an energy label for external doors, such as the one issued by BFRC, and the door equivalent of a Window Energy Rating. In an existing home in England, Approved Document L accepts band C for doors with more than 60% of the inside face glazed and band B for other doors, as alternatives to 1.4 W/m²K.
Actual-size U-value
An actual-size U-value is calculated for a window or door at the size and configuration it will be made, to BS EN ISO 10077-1 and 10077-2, rather than at a standard size. Under Approved Document L 2026, new homes need it, or a hot-box test, including sills, frame extenders, dummy sashes, glazing bars and couplers.
25% glazing rule
The 25% rule in Approved Document L says the windows, roof windows, rooflights and doors in an extension to a home in England should total no more than 25% of the extension's floor area, plus the area of any windows and doors it removes or covers. More glazing can still comply through an area-weighted U-value or SAP calculation.
Area-weighted U-value
An area-weighted U-value is the average U-value of a set of elements, found by multiplying each element's U-value by its area, adding the results and dividing by the total area. For an extension with more than 25% glazing, Approved Document L allows it to show the extension loses no more heat than a standard one of the same size and shape.
SAP (Standard Assessment Procedure)
SAP, the Standard Assessment Procedure, is the government-approved method for calculating the energy performance of homes, used to show that a new dwelling meets Part L; the 2026 edition of Approved Document L also names a newer method, the Home Energy Model, for new homes. SAP is also one way to show that an extension with more than 25% glazing complies.
g-value (solar factor)
The g-value is the share of the sun's energy that passes through glazing into the building, given as a number between 0 and 1; a lower g-value means less solar heat gain. It is determined under BS EN 410, alongside light transmittance.
Glass and glazing
Back to topInsulating glass unit (double glazed unit)
An insulating glass unit, or IGU, is two or more panes of glass held apart by a spacer around the edge and sealed, with the gap filled with air or an inert gas such as argon. A double glazed unit has two panes; its make-up is written as pane, gap and pane in millimetres, such as 4-16-4, and its product standard is BS EN 1279.
Triple glazing
Triple glazing is an insulating glass unit with three panes and two sealed gaps, which lowers heat loss compared with double glazing but adds weight and thickness. Approved Document L does not require it; it sets U-value limits that some designs meet with triple glazing.
Warm edge spacer
A warm edge spacer is the strip that separates the panes of an insulating glass unit, made from materials that conduct less heat than a traditional aluminium spacer, such as plastic, or thin stainless steel combined with plastic. It keeps the edge of the glass warmer, which lowers heat loss and the risk of condensation around the frame.
Low-E glass
Low-E (low-emissivity) glass has a thin, transparent coating that reflects long-wave heat back into the room while still letting daylight and solar energy in. In a double glazed unit it is usually the inner pane.
Solar control glass
Solar control glass has a coating that reflects or absorbs much of the sun's heat while letting through as much daylight as possible, giving a lower g-value. It is used where solar heat gain and overheating are a concern, such as on large glazed façades.
Annealed glass
Annealed glass is ordinary float glass that has not been heat treated or laminated, and it breaks into large, sharp pieces. It is not safety glass, so in a critical location Approved Document K only accepts it in small panes, at the thicknesses and sizes it sets out, or behind permanent protection.
Toughened glass
Toughened glass is glass heat treated to make it much stronger than ordinary glass of the same thickness, and if it breaks it shatters into small, relatively harmless pieces. Its standard is BS EN 12150, and it is the usual safety glass for doors, side panels and low windows.
Laminated glass
Laminated glass is two or more layers of glass bonded with plastic interlayers such as PVB, so that if it breaks the pieces stay stuck to the interlayer and the pane holds together. Its standard is BS EN 14449, and it is used for barriers, overhead glazing, security and noise reduction.
Safety glass
Safety glass is glass that breaks safely if it breaks, in practice toughened or laminated glass classified to BS EN 12600. Where it is used in a critical location, Approved Document K looks for Class 3 or better, or Class 2 or better for panes wider than 900 mm in a door or door side panel.
Critical location
A critical location is a place where people are likely to walk into glass, as defined in Approved Document K: glass in a door within 1500 mm of the floor, glass within 300 mm of either edge of a door and within 1500 mm of the floor, and any other glass in a wall, window or partition within 800 mm of the floor. Glass there must be safety glass or one of the accepted alternatives.
BS EN 12600
BS EN 12600 is the pendulum impact test that classifies flat glass by the drop height it survives and how it breaks, written as a code such as 1(C)2. The first number is the impact class (1 is the toughest test, 3 the lightest), and the letter shows how it breaks: A in the way typical of annealed glass, B of laminated glass, C of toughened glass.
Heat soak test
A heat soak test holds toughened glass at a high temperature for a set time so that panes containing nickel sulphide inclusions break in the factory rather than on the building. Heat soaked toughened glass is covered by BS EN 14179 and is often specified for façades.
Heat-strengthened glass
Heat-strengthened glass is heat treated to about one and a half to two times the strength of annealed glass and breaks into large pieces that tend to stay in the frame, so on its own it is not safety glass. Its standard is BS EN 1863, and it is often laminated, or used where glass runs hot, such as in front of spandrel panels.
Manifestation
Manifestation is permanent marking on large areas of clear glass so people can see it and do not walk into it. In buildings other than homes, Approved Document K asks for it at two heights, 850 to 1000 mm and 1400 to 1600 mm above the floor, unless the glass is already made obvious.
Glass weight
Glass weighs about 2.5 kg per square metre for each millimetre of thickness, because its density is about 2,500 kg/m³. A 4-16-4 double glazed unit has 8 mm of glass and weighs about 20 kg/m²; the gap adds nothing.
Aluminium frames and finishes
Back to topAluminium system
An aluminium system is a family of extruded profiles, gaskets, hardware and fixings designed and tested together by a system company, such as Schüco, Cortizo or Aluprof. A fabricator cuts and assembles the profiles into windows, doors or curtain walling to the drawings and the system's tested limits.
Sightline
A sightline is the visible width of frame you see across a window or door, usually quoted for the section where two panes or leaves meet. Slimline sliding doors have sightlines from about 20 mm to 30 mm, against about 110 mm to 120 mm where the panels of a Cortizo bifold meet.
Thermal break
A thermal break is an insulating barrier, usually polyamide, that separates the inner and outer parts of an aluminium frame so heat cannot conduct straight through the metal. Thermally broken frames lose far less heat and are much less prone to condensation than older aluminium frames without one.
Polyamide strip
A polyamide strip is the glass-fibre-reinforced plastic profile, typically PA66, that forms the thermal break in aluminium windows, doors and curtain walling by joining the inner and outer extrusions. Systems quote the depth of the thermal break, such as 45 mm on the Cortizo Bifold Plus.
Sash
A sash is the opening part of a window: a frame holding glass that is hinged, pivoted or slides within the fixed outer frame. Some door system makers also call each opening panel of a sliding or folding door a sash.
Leaf
A leaf is the opening part of a door, the panel that swings, slides, folds or pivots within the frame. A single door has one leaf, a double door two; a leaf with its frame and hardware is called a doorset.
Threshold
A threshold is the bottom section of a door frame that you step over. A flush or low threshold gives a near-level step between inside and out, while a weathered threshold stands higher to give more protection on a wall that takes driving rain; Approved Document M sets threshold guidance for accessible entrances.
Powder coating
Powder coating is a paint finish sprayed onto aluminium as a dry powder and cured in an oven into a hard, even coat, available in almost any RAL colour, gloss level and texture. On architectural aluminium the pretreatment and coating are commonly certified under the Qualicoat label.
Anodising
Anodising is an electrochemical process that thickens the natural oxide layer on aluminium to give a hard, metallic finish that is part of the metal rather than a coat on top. It comes in silver, bronze and other tones, and colour varies slightly between batches, so sample ranges are agreed first.
RAL colour
A RAL colour is a shade from the RAL Classic colour standard, identified by a four-digit number whose first digit gives the colour family, such as RAL 7016 anthracite grey or RAL 9005 jet black. Aluminium frames are usually specified by RAL number, sometimes with a different colour inside and out (dual colour).
PAS 24
PAS 24 is the BSI security test for doorsets and windows in the UK, checking that a complete new unit resists the kind of attack used by a casual or opportunistic burglar. The current version is PAS 24:2022+A1:2024, and meeting it is the usual way to satisfy Approved Document Q on new homes.
Door and window types
Back to topBifold door
A bifold door is a set of hinged glazed panels that fold against each other and slide along a track to one or both sides, opening up to about 90% of the opening. Sets usually have 2 to 7 panels, described by how they fold, such as 3+1 or 2+2.
Traffic door
A traffic door is a single panel in a bifold set that opens on its own like a normal door, so you can step in and out without folding back the whole set. It is common on 3-panel (2+1) and 4-panel (3+1) configurations.
Sliding door
A sliding door, or patio door, has large glazed leaves that slide past each other on parallel tracks, so nothing opens into the room or onto the patio. A two-track set opens about half the width, and slimline systems keep the frame between panes very narrow.
Lift-and-slide door
A lift-and-slide door is a sliding door whose handle lifts the leaf off its seals so it slides easily, then lowers it back onto them to seal tight when closed. The mechanism suits very large, heavy leaves, such as the 3 m by 3 m leaves of the Schüco ASS 70.HI.
Pocket door
A pocket door is a sliding door whose leaves slide into a cavity, or pocket, built into the wall, so the opening is completely clear when it is open. On large glazed sliding systems the pocket is built into the wall beside the opening, so it has to be designed in before the wall is built.
Pivot door
A pivot door is a door whose leaf turns on pivots at the top and bottom, set in from the edge of the leaf, instead of on hinges on the side of the frame. It allows very large, heavy leaves and is used for statement front doors and entrances.
French doors
French doors are a pair of hinged glazed doors that open from the middle, inwards or outwards. They usually suit openings up to about 1.8 m wide.
Tilt and turn window
A tilt and turn window opens two ways from one handle: tilted inwards at the top for ventilation, or swung fully inwards on side hinges like a door. Both the inside and outside of the glass can be cleaned from inside the room.
Shopfront
A shopfront is the glazed front of a shop or other commercial unit, usually an aluminium framed screen with an entrance door, display glass and sometimes a stallriser and fascia. Replacing one often needs planning permission and must meet Building Regulations for access, safety glass and energy.
Panic and emergency exit hardware
Panic exit hardware (BS EN 1125) opens an escape door with a horizontal push or touch bar and is used where the public may need to escape in a panic. Emergency exit hardware (BS EN 179) uses a lever handle or push pad and is for doors used by people who know the building.
Roof glazing
Back to topRoof lantern
A roof lantern is a glazed structure with sloping sides, usually aluminium framed, that rises above a flat roof on an upstand to bring daylight into the room below. Approved Document L treats it as a rooflight, with a limit of 2.2 W/m²K, and it counts towards the 25% glazing rule for extensions.
Rooflight
A rooflight, or skylight, is a glazed unit that admits daylight through a roof, installed out of the plane of the roof on a kerb or upstand. Flat rooflights, domes and roof lanterns are all rooflights; Approved Document L limits them to 2.2 W/m²K, calculated in the horizontal position.
Roof window
A roof window is a window fitted in the plane of the roof, unlike a rooflight, which sits on a kerb or upstand. It counts towards the 25% glazing rule for extensions in the same way as rooflights and doors.
Upstand (kerb)
An upstand, or kerb, is the raised frame on a flat roof that a rooflight or roof lantern sits on, lifting the glazing above the roof finish. Under Approved Document L, a kerb supplied with the rooflight is covered by its 2.2 W/m²K limit, while an upstand built on site should achieve 0.35 W/m²K or better.
A–Z index
Back to topA
B
C
R
S
U
Sources
Last checked . The rules quoted are for England; Wales and Scotland publish their own guidance. To cite a definition, link to https://www.bdfa.uk/glossary followed by the term's anchor, for example https://www.bdfa.uk/glossary#u-value. The main documents behind the definitions:
- Approved Document B: fire safety, Volumes 1 and 2 (GOV.UK)
- Approved Document K: protection from falling, collision and impact, 2013 edition (GOV.UK)
- Approved Document L: conservation of fuel and power, 2021 edition (GOV.UK)
- Approved Document L 2026 (GOV.UK)
- Approved Document M: access to and use of buildings (GOV.UK)
- Approved Document Q: security in dwellings (GOV.UK)
- The Building Regulations 2010, regulation 7 (legislation.gov.uk)
- Building Safety Act 2022 (legislation.gov.uk)
- Building control approval for higher-risk buildings (GOV.UK)
- Commission Decision 2000/367/EC on fire resistance classes (legislation.gov.uk)
- Competent person schemes (GOV.UK)
- Window and door energy ratings (BFRC)
- Centre for Window and Cladding Technology (CWCT)
Free tools
Specifying glazing for a project?
Send us the drawings, schedule or sizes and we'll price the system, glass and performance your project needs, from curtain walling to bifold doors.