How much glazing can your extension have? The 25% rule calculator

In England, the doors, windows, roof windows and rooflights in an extension should add up to no more than 25% of the extension's floor area, plus the area of any existing windows and doors the extension removes or covers. If your design has more glass than that, it can still comply through an area-weighted U-value calculation or a SAP calculation.

  • 25% of the floor area
  • openings removed or covered
  • your glazing allowance
Three aluminium roof lanterns on the flat roof of a single-storey extension
Roof lanterns count towards the 25%

Extension glazing calculator

Enter the floor area, then each door, window and rooflight in the extension, then any existing windows and doors it removes or covers. The example below is a 5 m by 4 m extension with a 4 m bifold door set and a roof lantern; change any figure to see your own result.

1 The extension's floor area

Measure the new floor inside the walls. If the extension opens into an existing room, ask your building control body which floor area they want you to use.

2 New doors, windows and rooflights

Add every door, window, roof window and rooflight in the extension, using the overall frame size. For a roof lantern or rooflight, count its glazed area: Approved Document L doesn't say whether to use the roof opening or the larger glazed surface, and the roof opening gives the smaller figure. If you're unsure, ask your building control body.

  • 8.40 m²
  • 2.00 m²
3 Existing windows and doors the extension removes or covers

The back door, kitchen window or patio doors in the wall the extension is built against. Their area is added to your allowance. Remove these rows if there are none.

  • 1.44 m²
  • 1.80 m²

Your result

Glazing allowance

Your 10.40 m² of glazing is 2.16 m² over the 8.24 m² allowance.

Extension floor area
20.00 m²
25% of the floor area
5.00 m²
Plus windows and doors removed or covered
+ 3.24 m²
Your glazing allowance
8.24 m²
Glazing you have entered
10.40 m²
Glazing as a share of the floor area
52%

Over the standard allowance by 2.16 m²

That doesn't rule the design out. You have three options:

  • Reduce the glazing by 2.16 m², for example a narrower door set or a smaller roof lantern.
  • Area-weighted U-value method (para 10.9): show that the extension's average U-value, weighted by area across its walls, roof, floor and openings, is no worse than the same-size extension built to the standard rules. Better-insulated walls, roof, floor or glazing can make up for the extra glass. For this method, Ikonografik has a free area-weighted U-value spreadsheet.
  • SAP calculation (para 10.10): show that the house plus your extension performs no worse on energy and emissions than the house plus a standard extension of the same size and shape. An energy assessor or your designer can prepare this.
See bifold door prices

The rule

“The total area of windows, roof windows, rooflights and doors in extensions should not exceed the sum of the following. i. 25% of the floor area of the extension. ii. The total area of any windows and doors which no longer exist or are no longer exposed due to the extension.”

Approved Document L, Volume 1: Dwellings, 2021 edition incorporating 2023 amendments, paragraph 10.7(d) (GOV.UK, PDF). The 2026 edition keeps the same rule as paragraph 10.8(d) (GOV.UK, PDF), from 24 March 2027. Alternatives: paragraphs 10.9 (area-weighted) and 10.10 (SAP) in both editions.

This is a guide, not a compliance check: your building control body decides. It follows the Approved Document for England.

How the 25% rule works

Approved Document L gives the 25% rule as part of the standard way to show an extension meets the energy efficiency requirements. You can check it by hand in three steps.

  1. Work out the extension's floor area in square metres, and take 25% of it.
  2. Add the area of the existing windows and doors that the extension removes, or that end up inside it and are no longer exposed to the outside. That total is your allowance.
  3. Add up every door, window, roof window and rooflight in the extension and compare the total with your allowance.

For example, a 5 m by 4 m extension has a floor area of 20 m², so 25% is 5 m². Built against a wall with a 1.2 m by 1.2 m kitchen window (1.44 m²) and a 0.9 m by 2.0 m back door (1.80 m²), it gets a further 3.24 m², for an allowance of 8.24 m². A 4.0 m by 2.1 m bifold door set (8.40 m²) and a 2.0 m by 1.0 m roof lantern (2.00 m²) come to 10.40 m², which is 2.16 m² over.

If you are only enlarging a window or adding a door in the existing house, with no extension, a different test applies: paragraph 10.5 looks at whether the windows, rooflights and doors exceed 25% of the whole house's floor area. Our guide to Building Regulations for bifold doors covers that case.

If your design is over the allowance

Going over 25% doesn't mean you can't have the glass. It means the standard check no longer applies, and you show compliance a different way. Agree the method with your building control body before you order doors or rooflights.

Area-weighted U-value method (paragraph 10.9)

You show that the area-weighted U-value of the extension is no worse than that of an extension of the same size and shape that meets the standard rules. Each element's U-value is multiplied by its area, the results are added up and divided by the total area. Better-insulated walls, roof, floor or glazing can make up for the extra glass.

SAP calculation (paragraph 10.10)

A SAP calculation shows that the house plus your extension performs no worse on primary energy, emissions and fabric energy efficiency than the house plus a notional extension of the same size and shape that follows the standard rules, including the 25% limit. An energy assessor or your designer can prepare it.

Reduce or rebalance the glazing

A narrower door set, a smaller roof lantern or one window fewer can bring the total back under the allowance. Whichever route you take, each new door, window and rooflight must still meet the U-value limits in Approved Document L (see the FAQs below).

Which edition of Approved Document L applies?

Where the 25% rule sits in each edition of Approved Document L, Volume 1 (England)
EditionApplies to25% ruleAlternatives
2021 edition, incorporating 2023 amendmentsWork in England now. It also covers work with a building notice, initial notice or full plans application given before 24 March 2027, if the work starts before 24 March 2028Paragraph 10.7(d)Paragraphs 10.9 and 10.10
2026 editionWork in England from 24 March 2027Paragraph 10.8(d), same ruleParagraphs 10.9 and 10.10

Dates are for building work that is not higher-risk building work; for that, the 2026 edition takes effect on 24 September 2027. Both editions are for use in England. Wales and Scotland publish their own guidance, so check with your local building control if you are building there.

Frequently asked questions

Choosing doors and rooflights for your extension? Send us the sizes and we'll price them.

0800 999 5575

What is the 25% glazing rule for extensions?

In England, Approved Document L says the total area of windows, roof windows, rooflights and doors in an extension should not exceed 25% of the extension's floor area, plus the area of any windows and doors that no longer exist or are no longer exposed because of the extension. It is paragraph 10.7(d) of the 2021 edition and paragraph 10.8(d) of the 2026 edition. A design with more glazing can still comply through an area-weighted U-value calculation or a SAP calculation.

Do roof lanterns and rooflights count towards the 25%?

Yes. The rule counts windows, roof windows, rooflights and doors, so a roof lantern, flat rooflight or roof window in the extension's roof adds to the total in the same way as the doors and windows in its walls.

Can I add the windows and doors my extension removes?

Yes. The area of any existing windows and doors that no longer exist, or are no longer exposed to the outside because of the extension, is added to the 25%. For a 20 m² extension built over a 1.2 m by 1.2 m kitchen window and a 0.9 m by 2.0 m back door, the allowance is 5 m² plus 3.24 m², which is 8.24 m².

Do solid doors count, or only glass?

The rule refers to doors without separating glazed and solid doors, so count every external door in the extension, not only the glass. If you are unsure how a particular door should be counted, ask your building control body.

What if my extension has more than 25% glazing?

Approved Document L gives two alternatives. Under paragraph 10.9, you show that the area-weighted U-value of the extension is no worse than that of an extension of the same size and shape that meets the standard rules, so better-insulated walls, roof, floor or glazing can make up for the extra glass. Under paragraph 10.10, a SAP calculation shows that the house plus your extension performs no worse on primary energy, emissions and fabric energy efficiency than the house plus a notional extension of the same size and shape. Agree the method with your building control body before you order doors.

Does the 25% rule change when the 2026 Approved Document L comes in?

No. The 2026 edition, which takes effect in England on 24 March 2027, keeps the same rule as paragraph 10.8(d), with the area-weighted and SAP alternatives at paragraphs 10.9 and 10.10. Under the transitional arrangements, work for which a building notice, initial notice or full plans application was given before 24 March 2027 stays under the previous rules if it starts before 24 March 2028.

Does the 25% rule apply to a conservatory?

Not to an exempt one. A conservatory or porch is exempt from the energy efficiency requirements if it is at ground level, has a floor area of no more than 30 m², has glazing that meets Part K, keeps (or replaces) the wall, door or window between it and the house, and the house's heating does not extend into it. A conservatory that is not exempt must meet the U-value standards, but the area limits do not apply. If the separation is removed or the heating is extended into it, it is treated as an extension and the 25% rule applies.

What U-values do new doors, windows and rooflights in an extension need?

Approved Document L sets limits for new fittings in existing homes, including extensions: 1.4 W/m²K or Window Energy Rating Band B for windows, 2.2 W/m²K for rooflights, 1.4 W/m²K or Doorset Energy Rating Band C for doors with more than 60% of the internal face glazed, and 1.4 W/m²K or Doorset Energy Rating Band B for other doors. These are Table 4.2 of the 2021 edition and Table 3.2 of the 2026 edition, which give the same figures.

Sources

Last checked against the documents themselves. To cite this tool, link to https://www.bdfa.uk/extension-glazing-calculator.