The 2026 edition of Approved Document L, the guidance behind the Future Homes and Buildings Standards, applies in England from 24 March 2027, or 24 September 2027 for higher-risk building work. For windows, doors, rooflights and roof lanterns, the maximum U-values do not change. What changes is how a new home's windows and doors are rated: each U-value must be hot-box tested or calculated at the unit's actual size and configuration, including sills, frame extenders, dummy sashes and couplers. Replacements in existing homes keep the 1.4 W/m²K limit, the 25% extension glazing rule stays, and non-domestic limits, including 1.6 W/m²K for curtain walling, are unchanged. We read every figure below from the gov.uk documents on 23 November 2026 and give the paragraph or table number for each.

When does Approved Document L 2026 come into force?

The Building Regulations etc. (Amendment) (England) Regulations 2026 come into force on 24 March 2027. For higher-risk building work, and work to an existing higher-risk building, the date is 24 September 2027. Both dates are in Building Circular 01/2026, issued on 24 March 2026 alongside the new Approved Document L. Both volumes were reissued on 8 September 2026 to correct minor errors.

Work already in the system stays under the 2021 edition. The changes do not apply where a building notice, initial notice or full plans application was given before 24 March 2027, as long as work on that building starts before 24 March 2028. For higher-risk building work, the cut-off is a valid building control approval application made to the Building Safety Regulator before 24 September 2027. For design and construction, higher-risk buildings are buildings with at least two residential units, care homes and hospitals that are at least 18 metres high or have at least seven storeys.

The same regulations also revoke older transitional arrangements from 2013 and 2021 that let some sites keep building to 2010 energy standards, with some exceptions. If you are building out an old consent, ask your building control body which standard now applies.

Part L 2021 vs 2026: limiting U-values for windows, doors and rooflights

The tables give the maximum U-values in W/m²K; lower means less heat lost. Volume 1 covers dwellings. Volume 2 covers every other building, including hotels, hostels and halls of residence. In a mixed-use block the flats follow Volume 1 and the shops or offices Volume 2.

Homes (Approved Document L Volume 1), maximum U-value in W/m²K
Situation2021 edition2026 edition (from 24 March 2027)
New home: windows, roof windows and curtain walling1.6 (Table 4.1)1.6 (Table 3.1), now hot-box tested or calculated at actual size (paras 3.2 and 3.3)
New home: doors, including glazed doors1.6 (Table 4.1)1.6 (Table 3.1), now hot-box tested or calculated at actual size (paras 3.2 and 3.3)
New home: rooflights and roof lanterns2.2 (Table 4.1)2.2 (Table 3.1)
Existing home: new or replacement window1.4, or Window Energy Rating band B (Table 4.2)1.4, or Window Energy Rating band B (Table 3.2)
Existing home: door with more than 60% of the inside face glazed, such as most glazed bifold, sliding and French doors1.4, or Doorset Energy Rating band C (Table 4.2)1.4, or Doorset Energy Rating band C (Table 3.2)
Existing home: other doors1.4, or Doorset Energy Rating band B (Table 4.2)1.4, or Doorset Energy Rating band B (Table 3.2)
Existing home: external fire doorset1.8 (Table 4.2, note 14)1.8 (Table 3.2, note 12)
Existing home: rooflight or roof lantern2.2 (Table 4.2)2.2 (Table 3.2)
Extension: total area of windows, doors and rooflights25% of the extension floor area, plus the openings it removes or covers (para 10.7(d))The same rule (para 10.8(d))
Listed building or conservation area, where 1.4 would harm the characterCentre-pane 1.2, or low-e secondary glazing (para 4.10)Centre-pane 1.2, or low-e secondary glazing (para 3.11)
Buildings other than dwellings (Approved Document L Volume 2), maximum U-value in W/m²K
Element2021 edition2026 edition (from 24 March 2027)
Windows, roof windows and curtain walling1.6 (Table 4.1)1.6 (Table 3.1)
Windows in buildings similar to dwellings, such as student accommodation and care homes1.6, or Window Energy Rating band B (Table 4.1)1.6, or Window Energy Rating band B (Table 3.1)
Pedestrian doors, including glazed doors1.6 (Table 4.1)1.6 (Table 3.1)
High-usage entrance doors3.0 (Table 4.1)3.0 (Table 3.1)
Vehicle access and similar large doors1.3 (Table 4.1)1.3 (Table 3.1)
Rooflights2.2 (Table 4.1)2.2 (Table 3.1)
Display windows, such as shopfrontsNo maximum; counted in a new building's energy calculation (Table 4.1, note 10)No maximum; counted in a new building's energy calculation (Table 3.1, note 10)
Buildings with high internal heat gainsWindow average can be higher, but no window above 2.7 (Table 4.1, note 11)Window average can be higher, but no window above 2.7 (Table 3.1, note 11)

So the numbers to beat are the same in both editions. What changes for glazing is how a new home's figure is worked out, and the tougher whole-building energy targets that new homes and buildings must meet.

The main change: actual-size U-values for windows and doors in new homes

A window's U-value covers the whole unit, glass and frame together (para 3.1). Under the 2021 edition, any home could use a calculation at actual size, a calculation for a standard 1.23m by 1.48m window or standard door sizes, a hot-box test, or a default value from SAP Table 6e (paras 4.2 to 4.4). From 24 March 2027 a new home has two options (para 3.2): a hot-box test to BS EN ISO 12567-1 (12567-2 for roof windows), or a calculation at the actual size and configuration to BS EN ISO 10077-1 and 10077-2. Paragraph 3.3 lists what the figure must include, where present:

  • the actual frame sections, for example outer frames of different widths
  • sills and thresholds
  • add-ons and frame extenders, for example 15mm or 30mm
  • dummy sashes, dummy transoms and dummy mullions
  • decorative glazing bars inside the glass unit, such as Georgian bars
  • couplers that carry no dead load, such as a PVC H-coupler (load-bearing parts such as bay poles are left out)

The government's consultation response says it kept this approach, minus some structural elements consultees found problematic, so that design calculations match real performance more closely (paras 12.41 and 12.42). In practice each window and door on a new home's schedule can now have its own U-value: the whole-unit figure mixes glass, frame and glass edge, so the same system scores differently at another size or with an extra sash or coupler. A standard-size brochure figure is no longer enough.

The limits are a backstop, not the target

A new home must also meet energy and emission targets set by a notional dwelling of the same size and shape (paras 1.1 to 1.3), specified in The Future Homes Standard 2026: dwelling notional buildings and SAP 10.3 Appendix R. The note under Table 3.1 warns that some elements will need to be significantly better than the limits, so your energy assessor may ask for well below 1.6. Where thicker glass is needed for wind load, safety, security or acoustics, an equivalent unit with standard 6mm glass should be shown to meet the limit (Table 3.1, note 4).

What stays the same for replacement windows and doors

In an existing home, new and replacement windows and doors keep the 2021 limits: 1.4 W/m²K, or Window Energy Rating band B, Doorset Energy Rating band C for doors more than 60% glazed, and band B for other doors (Table 3.2). The figure can still be calculated at the standard 1.23m by 1.48m window size or standard door sizes, hot-box tested, or taken from the SAP 10.3 Table 6e defaults (paras 3.4 and 3.5), and a replacement must be no worse than what it replaces (para 3.9). So a like-for-like replacement faces the same numbers whether it is fitted before or after 24 March 2027.

  • Replacement units should be draught-proofed, with insulated cavity closers where appropriate (para 10.3).
  • Building control may accept a Window or Doorset Energy Rating from a certification scheme with an audit trail to installation (para 10.4).
  • Replacing only the glass, or a window or door in its existing frame, is not a "controlled fitting" and does not have to meet the energy rules (para 10.6).

Watch for the new-build figure being quoted for replacements

Some sellers' pages about the 2026 changes say a replacement window or door needs only 1.6 W/m²K, or quote a 1.2 centre-pane figure. Neither is right for a house. 1.6 is the limit for new homes (Volume 1, Table 3.1) and non-domestic buildings (Volume 2, Table 3.1); for an existing home it is 1.4 or the energy rating (Volume 1, Table 3.2). The 1.2 centre-pane figure measures the glass alone and is only the fallback for listed buildings and conservation areas (para 3.11). When comparing quotes, ask for the whole-window or whole-door U-value, or the energy rating certificate. Our U-value checker shows which limit applies to your window or door.

On the bifold doors we make, the Schüco AS FD 90.HI has a published U-value of 1.0 W/m²K and the Cortizo Bifold Plus goes down to 0.8 W/m²K, both inside 1.4. Your doors' figure depends on the glass and panel sizes, so we confirm it when we quote.

Extensions: the 25% glazing rule does not change

An extension can comply by the elemental method, an area-weighted U-value calculation or a SAP calculation (para 10.7). Under the elemental method, new windows, rooflights and doors meet the existing-home limits, so 1.4 and 2.2 rather than the new-home 1.6 (para 10.8(c)). Their total area, rooflights and roof lanterns included, should not exceed 25% of the extension's floor area plus the area of windows and doors that no longer exist or are no longer exposed because of it (para 10.8(d)), the same rule as para 10.7(d) in 2021.

For example, a 20m² extension that covers an existing 1.5m² window and 2m² back door may have 5m² plus 3.5m², so 8.5m² of openings. A bifold 3.6m wide and 2.1m high is 7.56m², and adding a 1.2m² side window takes it to 8.76m², over the allowance.

Going over is allowed through the other routes. The area-weighted route (para 10.9) shows the extension's area-weighted U-value is no worse than that of an extension of the same size and shape built to the elemental rules, so better-performing elements can offset extra glass. The SAP route (para 10.10) compares the home plus the extension with the home plus a notional extension whose openings follow the 25% rule. Separately, enlarging or adding a window so the home's openings exceed 25% of its total floor area calls for other energy improvements (para 10.5). Our bifold doors and building regulations guide covers the other rules, and our bifold door cost guide gives typical prices. Our extension glazing calculator works out your allowance.

Rooflights and roof lanterns under Part L 2026

Approved Document L defines a rooflight as a glazed unit installed out of plane with the roof on a kerb or upstand, sometimes called a skylight; a roof window sits in the plane of the roof (Appendix A). A roof lantern on an upstand fits the rooflight definition. The limit stays at 2.2 W/m²K in homes (Tables 3.1 and 3.2) and other buildings (Volume 2, Table 3.1), and the rules below are carried over from 2021:

  • Rooflights are calculated in the horizontal position, windows and roof windows vertically; data for the wrong plane is adjusted using BR 443 (para 3.6).
  • The U-value is based on the developed surface area, often larger than the roof opening (Table 3.1, note 6).
  • A kerb supplied with the rooflight as one assembly is covered by the 2.2 limit; an upstand built on site should not exceed 0.35 W/m²K (Table 3.1, note 7).

On a flat-roof extension, size the aluminium roof lantern and the garden doors together, because both count towards the 25%.

Curtain walling, commercial windows and doors (Volume 2)

For buildings other than dwellings, the limits and methods are unchanged. A window is calculated at actual size or hot-box tested; only in buildings similar to dwellings may it be calculated at the standard 1.23m by 1.48m size, and standard configurations should not be used for commercial windows (Volume 2, para 3.2, as 2021 para 4.2). In a new building the 1.6 W/m²K for windows and curtain walling is an area-weighted average; for new units in existing buildings it applies to each one (Table 3.1, note 1).

The government decided against a separate category, lesser standard or dispensation for curtain walling (consultation response, para 12.50). On a new block of flats, curtain walling counts as a window under Volume 1 (Table 3.1, note 5), so agree early with the energy assessor and building control how the actual-size rule in para 3.2 will be met for those elevations. Our curtain walling specification guide covers the other figures to specify, such as g-value and condensation risk.

Where an extension to a non-domestic building would have a higher share of glazing than the existing building, windows and pedestrian doors are capped at 30% of exposed wall for residential buildings, 40% for places of assembly, offices and shops and 15% for industrial and storage buildings, with rooflights at 20% of the roof (para 9.10 and Table 9.1, unchanged from Table 10.1 in 2021). Display windows and vehicle doors can be as large as needed. An extension over 100m² that is also more than 25% of the existing floor area is treated as a new building (para 9.7).

What to do now

Homeowners

  • Replacing windows or doors: the limits are the same either side of 24 March 2027, so there is no need to wait or rush. Ask for the whole-unit U-value or energy rating.
  • Planning an extension: the 25% rule is unchanged, and which edition applies depends on when the building notice or plans went in and when work starts, not on when you order the doors.

Builders and developers

  • Check which plots are protected: a building notice, initial notice or full plans application given before 24 March 2027, with work on that building started before 24 March 2028.
  • For new homes outside that protection, ask your supplier for a U-value for every unit on the schedule, calculated at actual size to BS EN ISO 10077-1 and 10077-2 (or hot-box tested), and pass it to the energy assessor.

Architects and specifiers

  • Settle dummy sashes, applied transoms, Georgian bars and frame extenders before the energy model is fixed, as they now count in the figure (para 3.3).
  • Where thicker glass is needed, have the supplier show the equivalent unit with standard 6mm glass meets the limit (Table 3.1, note 4).
  • Check whether a residential scheme is a higher-risk building, which moves its date to 24 September 2027.

For commercial windows we already calculate the U-value for the actual window schedule rather than quoting a brochure figure, and curtain walling U-values are calculated on the actual elevation.

This guide is general information, not a compliance check: your building control body decides what applies to your project. We will update it if the government revises the documents again.

Frequently asked questions

When does Approved Document L 2026 come into force?

On 24 March 2027 in England, or 24 September 2027 for higher-risk building work. Work covered by a building notice, initial notice or full plans application given before 24 March 2027 stays under the 2021 edition if it starts before 24 March 2028.

Do replacement windows have to meet the Future Homes Standard?

Not in the sense of a new limit. Replacement windows in an existing home still need 1.4 W/m²K or Window Energy Rating band B, as in the 2021 edition, and can still be rated at the standard 1.23m by 1.48m size. The actual-size calculation applies to new homes.

What U-value do replacement doors need from 2027?

In an existing home in England, 1.4 W/m²K or better, or Doorset Energy Rating band C for doors more than 60% glazed and band B for other doors, the same as in 2021. The 1.6 figure sometimes quoted is the limit for doors in new homes and non-domestic buildings.

Will I need triple glazing after 24 March 2027?

Approved Document L does not require triple glazing. It sets U-value limits for the whole window or door, and how they are met is up to the system and the glass. On a new home the energy calculation may call for better than 1.6, and triple glazing is one way to get there.

Does the 25% glazing rule for extensions change in 2026?

No. Windows, roof windows, rooflights and doors in an extension should still total no more than 25% of its floor area plus the openings it removes or covers (para 10.8(d), previously 10.7(d)). The area-weighted or SAP routes can still justify more glass.

Do roof lanterns count towards the 25% extension glazing limit?

Yes. Rooflights count towards the 25%, and a roof lantern on an upstand fits the Approved Document L definition of a rooflight. Its own limit is 2.2 W/m²K, calculated in the horizontal position.

What is an actual-size U-value?

The U-value of a window or door calculated at the size and configuration it will be made, to BS EN ISO 10077-1 and 10077-2, rather than at a standard size. For new homes from 24 March 2027 it includes sills, frame extenders, dummy sashes, glazing bars and couplers. A hot-box test is the alternative.

What U-value does curtain walling need under Part L 2026?

1.6 W/m²K, as in 2021, in buildings other than dwellings (Volume 2, Table 3.1) and in new homes, where it counts as a window (Volume 1, Table 3.1). There is no separate or lesser standard for curtain walling, and the whole-building energy calculation usually asks for better.

If I order windows now and they are fitted after 24 March 2027, which rules apply?

The order date does not decide it. For a replacement in an existing home the limits are the same in both editions. For a new home or extension, the 2021 edition applies if the building notice, initial notice or full plans application went in before 24 March 2027 and work starts before 24 March 2028.

Sources and further reading

Specifying windows, doors, curtain walling or rooflights for a project that will fall under the 2026 edition? Send the drawings or window schedule and we will price the systems, and calculate window, door and curtain walling U-values for the actual sizes. Homeowners can ask for a free quote or see typical prices in our bifold door cost guide.

Get a free quote