Does this window or door meet Part L? The U-value checker

In England, a new or replacement window or door in an existing home needs a whole-unit U-value of no more than 1.4 W/m²K, or the energy rating band Approved Document L allows. In a new home, and for most windows, curtain walling and doors in other buildings, the limit is 1.6 W/m²K; rooflights can be up to 2.2 W/m²K. The 2026 edition, which applies from 24 March 2027, keeps the same figures.

  • Existing home1.4 W/m²K
  • New home1.6 W/m²K
  • Other buildings1.6 W/m²K
  • Rooflights2.2 W/m²K
Three-pane aluminium window with dark grey frames and a brick sill, set in a red brick wall
The U-value covers glass and frame together

U-value checker

Choose the building, the work and the product, then enter its U-value. The example below is a replacement glazed bifold door in an existing home with a U-value of 1.3 W/m²K; change any answer to check your own.

1 What is the building?

Homes follow Approved Document L Volume 1. Offices, shops, schools, hotels, student accommodation and other buildings follow Volume 2. In a mixed-use block, the flats follow Volume 1. This tool is for England.

2 What is the work?
3 The product and its U-value

Use the figure for the whole door, frame and glass together (Ud), not the centre-pane glass figure (Ug) or the frame alone (Uf). Approved Document L assesses the whole element (2021 paragraph 4.1; 2026 paragraph 3.1).

Your result

Does it meet Part L?

Meets the limit. 1.3 W/m²K is no higher than the 1.4 W/m²K maximum for a door more than 60% glazed in an existing home.

Approved Document L
Volume 1
Work
An existing home
Product
Door with more than 60% of its inside face glazed (most bifold, sliding and French doors)
Limiting value
1.4 W/m²K or Doorset Energy Rating band C
Your product
1.3 W/m²K
  • In force now

    2021 edition, incorporating 2023 amendments

    Meets the limit

    1.4 W/m²K or Doorset Energy Rating band C: Table 4.2, paragraphs 4.7, 4.8 and 10.3

  • From 24 March 2027

    2026 edition

    Meets the limit

    1.4 W/m²K or Doorset Energy Rating band C: Table 3.2, paragraphs 3.8, 3.9 and 10.3

The 2026 edition applies to work in England from 24 March 2027 (24 September 2027 for higher-risk building work). Work with a building notice, initial notice or full plans application given before 24 March 2027 stays under the 2021 edition if it starts before 24 March 2028.

  • A replacement must also be no worse than the old one. A replacement element should be no worse than the one it replaces as well as meeting the table (2021 paragraph 4.8; 2026 paragraph 3.9). Replacing only the glass, or a window or door in its existing frame, is not a “controlled fitting” and does not need to meet the energy rules (paragraph 10.6).
Read the Part L 2026 guide

Compare with our systems

These product pages list each system's U-value. Your unit's figure depends on its size and glass, so we confirm it when we quote.

The rule

Table 4.2, “Doors with >60% of internal face glazed”: maximum U-value 1.4 W/(m²·K) or Doorset Energy Rating Band C minimum.

Approved Document L, Volume 1: Dwellings, 2021 edition incorporating 2023 amendments, Table 4.2 (GOV.UK, PDF). The 2026 edition gives the same figure in Table 3.2 (GOV.UK, PDF), from 24 March 2027.

This is a guide, not a compliance check: your building control body decides. It follows the Approved Documents for England.

How the checker decides

Approved Document L sets a limiting U-value, a maximum, for each kind of window, door and rooflight. The checker finds the right one in three steps.

  1. Which volume. Homes follow Volume 1: Dwellings. Every other building, including hotels, student accommodation, offices and shops, follows Volume 2.
  2. Which table. In Volume 1, new homes use Table 4.1 (Table 3.1 in the 2026 edition), and new or replacement windows, doors and rooflights in existing homes and extensions use Table 4.2 (Table 3.2). In Volume 2, one table covers new and existing buildings: Table 4.1 (Table 3.1).
  3. Compare. The tables give a “Maximum U-value”, so a product meets the limit when its whole-unit U-value is the same as or lower than the figure. In an existing home, a Window or Doorset Energy Rating band can be used instead, where the table allows it.

For example, a replacement window in a house rated 1.5 W/m²K does not meet the 1.4 limit for an existing home, but the same window would meet the 1.6 limit in a new home or an office. A 1.6 figure quoted for a replacement window in a house is the new-home limit, not the one that applies.

Limiting U-values for windows, doors and rooflights

Maximum U-value in W/m²K, Approved Document L (England). The figures are the same in both editions.
ElementMaximum U-value2021 edition2026 edition
New home (Volume 1)
Windows, roof windows and curtain walling1.6Table 4.1Table 3.1
Doors, including glazed doors1.6Table 4.1Table 3.1
Rooflights and roof lanterns2.2Table 4.1Table 3.1
Existing home or extension (Volume 1)
Windows, roof windows and curtain walling1.4, or Window Energy Rating band BTable 4.2Table 3.2
Doors with more than 60% of the inside face glazed1.4, or Doorset Energy Rating band CTable 4.2Table 3.2
Other doors1.4, or Doorset Energy Rating band BTable 4.2Table 3.2
External fire doorsets1.8Table 4.2, note 14Table 3.2, note 12
Rooflights and roof lanterns2.2Table 4.2Table 3.2
Other buildings, new or existing (Volume 2)
Windows, roof windows and curtain walling1.6Table 4.1Table 3.1
Windows in buildings similar to homes, such as student accommodation and care homes1.6, or Window Energy Rating band BTable 4.1Table 3.1
Pedestrian doors, including glazed doors1.6Table 4.1Table 3.1
External fire doorsets1.8Table 4.1, note 14Table 3.1, note 14
High-usage entrance doors3.0Table 4.1Table 3.1
Vehicle access and similar large doors1.3Table 4.1Table 3.1
Rooflights2.2Table 4.1Table 3.1
Roof ventilators, including smoke vents3.0Table 4.1Table 3.1
Display windows and similar glazingNo maximumTable 4.1, note 10Table 3.1, note 10

In a new building, the Volume 2 figures are area-weighted averages; for new windows, rooflights and doors in an existing building they apply to each unit (note 1). In Volume 1 the new-home figures are area-weighted averages and the existing-home figures apply to each window, door and rooflight.

When meeting the limit is not enough

The limiting values are a backstop. Depending on the work, Approved Document L asks for more than a product that meets the table.

New homes have energy targets

A new home must also meet its target primary energy rate, target emission rate and target fabric energy efficiency rate (paragraph 2.3). The note under Table 4.1 (Table 3.1 in 2026) says some elements will need to be significantly better than the limiting standards to meet the fabric target. Your energy assessor sets the figure each unit needs.

New homes from 24 March 2027: actual-size U-values

Under the 2026 edition, a new home's window and door U-values come from a hot-box test or a calculation at the actual size and configuration of each unit, including sills, thresholds, frame extenders, dummy sashes and couplers (paragraphs 3.2 and 3.3). A brochure figure for a standard-size window is no longer enough for a new home.

New buildings have targets too

A new office, shop or other non-domestic building must not exceed its target primary energy rate and target emission rate, based on a notional building of the same size and shape (Volume 2, paragraphs 1.1 and 2.3).

Replacements and extensions

A replacement should be no worse than the unit it replaces (2021 paragraph 4.8; 2026 paragraph 3.9), be draught-proofed and have insulated cavity closers where appropriate (paragraph 10.3). An extension's openings also have an area limit: try our extension glazing calculator.

Which edition of Approved Document L applies?

Approved Document L editions for England, and where the window and door limits sit
EditionApplies toVolume 1 tablesVolume 2 table
2021 edition, incorporating 2023 amendmentsWork in England now. It also covers work with a building notice, initial notice or full plans application given before 24 March 2027, if the work starts before 24 March 2028Table 4.1 (new homes), Table 4.2 (existing homes)Table 4.1
2026 editionWork in England from 24 March 2027Table 3.1 (new homes), Table 3.2 (existing homes)Table 3.1

Dates are for building work that is not higher-risk building work; for that, the 2026 edition takes effect on 24 September 2027, with its own transitional rules. Both editions are for use in England. Wales and Scotland publish their own guidance, so check with your local building control if you are building there.

Frequently asked questions

Need windows, doors or curtain walling to a set U-value? Send us the schedule and we'll price it.

0800 999 5575

What U-value do replacement windows need in England?

A new or replacement window in an existing home needs a U-value of no more than 1.4 W/m²K, or a Window Energy Rating of band B or better. That is Table 4.2 of Approved Document L Volume 1, 2021 edition, and Table 3.2 of the 2026 edition, which give the same figure. The U-value is for the whole window, glass and frame together, and a replacement should also be no worse than the window it replaces.

What U-value do bifold, sliding and French doors need?

In an existing home or an extension, a door with more than 60% of its inside face glazed, which covers most bifold, sliding and French doors, needs 1.4 W/m²K or a Doorset Energy Rating of band C or better. Other doors in an existing home need 1.4 W/m²K or band B. In a new home, doors including glazed doors have a limit of 1.6 W/m²K. The figures are the same in the 2021 and 2026 editions.

If the limit is 1.4 and my window is 1.4, does it pass?

Yes. The tables in Approved Document L give a maximum U-value, so a product exactly on the limit meets it, while 1.41 W/m²K would not. Make sure the figure is the whole-window U-value worked out the way the Approved Document allows: for a new home from 24 March 2027, that means a hot-box test or a calculation at the actual size and configuration of each unit.

What U-value do windows and doors need in a new-build house?

No more than 1.6 W/m²K for windows, roof windows and curtain walling, 1.6 W/m²K for doors including glazed doors, and 2.2 W/m²K for rooflights (Table 4.1 of the 2021 edition, Table 3.1 of the 2026 edition). These are area-weighted averages and a minimum, not the target. The house must also meet its primary energy, emission and fabric energy efficiency targets, and Approved Document L notes that some elements will need to be significantly better than the limits to meet the fabric target.

What U-value do commercial windows, curtain walling and doors need?

In buildings other than homes, Approved Document L Volume 2 sets 1.6 W/m²K for windows, roof windows, curtain walling and pedestrian doors, 3.0 W/m²K for high-usage entrance doors, 1.3 W/m²K for vehicle access and similar large doors, 2.2 W/m²K for rooflights and 3.0 W/m²K for roof ventilators, including smoke vents. External fire doorsets may be up to 1.8 W/m²K. No maximum is set for display windows and similar glazing, such as a shop window that meets the definition in Appendix A. These are Table 4.1 of the 2021 edition and Table 3.1 of the 2026 edition.

Do the U-value limits change with Approved Document L 2026?

No. The 2026 edition, which applies in England from 24 March 2027 (24 September 2027 for higher-risk building work), keeps every limiting U-value for windows, doors and rooflights. What changes for new homes is how the figure is worked out: each window and door U-value must come from a hot-box test or a calculation at its actual size and configuration (paragraphs 3.2 and 3.3). Work with a building notice, initial notice or full plans application given before 24 March 2027 stays under the 2021 edition if it starts before 24 March 2028.

Which U-value should I use: Uw, Ug or Uf?

Use the whole-unit figure, often labelled Uw for a window and Ud for a door or rooflight. Approved Document L assesses the whole element, glass and frame together (2021 paragraph 4.1; 2026 paragraph 3.1). Ug is the centre-pane figure for the glass and Uf the figure for the frame, so neither is the number to check. The only centre-pane limit in the Approved Document, 1.2 W/m²K, is for windows and fully glazed doors that cannot meet the normal limit because the character of the building must be kept.

Do I need to meet the U-value if I only replace the glass?

No. In a home, replacing only the glass, or a window or door in its existing frame, is not providing a controlled fitting, and Approved Document L says such work does not need to meet the energy efficiency requirements (paragraph 10.6 in both editions). Replacing the whole unit, frame included, does: the new unit should meet the limiting value, be draught-proofed and have insulated cavity closers where appropriate (paragraph 10.3).