Replacing a shopfront in England usually needs planning permission, because a new shopfront normally changes how the building looks and the permitted development rights for shops expressly exclude new or replaced shop fronts and security shutters. Signs may also need advertisement consent, a listed building needs listed building consent, and the installation is building work under the Building Regulations: Parts K and L always, and Parts M and B where the entrance or escape route is altered. This guide, for shop owners, landlords and fit-out contractors, takes each in turn, with the figures that shape the design and a checklist of what to send for a quote. For the frontages we design, make and install, see aluminium shopfronts.
| Work | What usually applies | Where it comes from |
|---|---|---|
| New, altered or replaced shopfront | Planning permission, where the work materially affects the outside appearance of the building | Town and Country Planning Act 1990, s.55; no permitted development (GPDO 2015, Schedule 2, Part 7, Class A.1(h)) |
| Like-for-like repair or redecoration | Usually no planning permission; listed building consent can still be needed on a listed building | Town and Country Planning Act 1990, s.55(2)(a) |
| External security shutter or grille | Planning permission; many councils resist solid shutters | GPDO 2015, Schedule 2, Part 7, Class A.1(i); borough shopfront guides |
| Non-illuminated fascia or hanging sign | Often deemed consent, if it meets the size, height and content conditions | Advertisement Regulations 2007, Schedule 3, Class 5 |
| Illuminated sign | Deemed consent only within strict limits and never in a conservation area; otherwise express advertisement consent | Advertisement Regulations 2007, Schedule 3, Class 4B |
| Any of the above on a listed building | Listed building consent for works that affect its character | Planning (Listed Buildings and Conservation Areas) Act 1990, s.7 |
| Replacing the frame and glass | Building Regulations: Parts K and L; Part M where the entrance is altered; Part B where the door is an escape route | Building Regulations 2010; Approved Documents M, K, L and B |
Do you need planning permission to replace a shopfront?
Usually, yes. Under section 55 of the Town and Country Planning Act 1990, building works need planning permission unless they affect only the interior or do not materially affect the external appearance. A different frame material or colour, a moved door, a new stallriser (the solid panel below the display glass), a deeper fascia or a new glazing layout can all materially affect the appearance.
There is no permitted development route for the shopfront itself. Class A of Part 7 of the General Permitted Development Order 2015 lets commercial premises be extended or altered within limits, but paragraph A.1(h) excludes a new shop front and the alteration or replacement of an existing one, and A.1(i) excludes installing or replacing a security grille or shutter on a shop front. Class A allows no alterations at all on "article 2(3) land", which includes conservation areas, National Parks and World Heritage Sites.
The London Borough of Brent's shopfronts guidance puts it simply: "most alterations to a shop front will require planning permission. However, routine maintenance works generally do not." Repainting in the same colour or replacing broken glass in the existing frame is maintenance; a new frontage is not. If you are unsure, ask the council for pre-application advice, or apply for a lawful development certificate confirming that the work does not need permission.
For an application that is not major development, the council has 8 weeks from receiving a valid application to decide it, unless a longer period is agreed in writing. The frontage can be surveyed, drawn and priced meanwhile, but wait for the decision before fabrication starts, because conditions can change materials or details.
What to send with a shopfront planning application
Each council publishes its own validation list, so check it before you apply. London borough shopfront guides give a good idea of what is expected:
- A location plan (Kingston asks for 1:1250), the application form and the fee
- Elevations of the shopfront and signs showing part of the neighbouring units and the upper floor, with at least one cross section (Kingston asks for 1:50 drawings and 1:20 details)
- A recent dated photograph of the shop and the units either side
- A design statement showing how the design follows the council's guidance; Brent says applications without one are unlikely to succeed
Shop signs: advertisement consent and deemed consent
Signs are controlled separately, under the Town and Country Planning (Control of Advertisements) (England) Regulations 2007. Outside signs on a shop need either express consent from the council or deemed consent, which applies automatically to signs that fit a class in Schedule 3 and meet its conditions. The Planning Portal notes that many traditional, non-illuminated fascia and hanging signs are likely to have deemed consent, and that displaying an advertisement without consent is a criminal offence.
| Class 5: signs on business premises | Class 4B: illuminated signs on business premises | |
|---|---|---|
| What it covers | Signs referring only to the business, its goods or services; on a shop, only on a wall with a shop window | Illuminated signs with the same content and the same shop-window rule |
| Illumination | Not allowed (narrow exceptions for medical and veterinary services) | Static only, no flashing or moving parts; halo lighting or lit letters on an unlit background; no more than 600 cd/m² (300 cd/m² over 10 m²) |
| Height | Top no higher than 4.6 m above ground or the bottom of any first-floor window, whichever is lower | Bottom at least 2.5 m above ground; top no higher than 4.6 m or the bottom of any first-floor window |
| Lettering | No character over 0.75 m high | No character over 0.75 m high; light box no more than 0.25 m deep |
| Projecting signs | See the Class 5 conditions in Schedule 3 | One projecting sign: no more than 0.75 m², 1 m high, projecting 1 m or two-thirds of the footway width, never over the carriageway |
| Where it does not apply | Tighter limits in an area of special control | Not in conservation areas, National Parks, Areas of Outstanding Natural Beauty or the Broads |
Where express consent is needed, local guidance decides what the council will approve. Brent's guidance says internally illuminated signs will not normally be permitted and illuminated projecting or hanging signs are not permitted; the Royal Borough of Kensington and Chelsea's Shopfront Design Guidelines SPD sets out the signs it expects with a new shopfront. On a listed building, a new sign usually needs listed building consent too.
Security shutters and grilles: do they need planning permission?
External shutters and grilles need planning permission, because permitted development excludes installing or replacing a security grille or shutter on a shop front. Councils also tend to resist solid shutters. Brent says solid or pin-hole roller shutters "fail to contribute positively" to the street and can attract graffiti, and sets out its preferences in order:
- Laminated and toughened glass in the shopfront itself
- An internal, open-type shutter behind the glass, stored out of sight during trading hours; Brent says these need no planning permission unless the building is listed, when listed building consent is needed
- An external shutter only where it is shown to be necessary for insurance, open type, powder coated to match, with the box and guide rails concealed behind the fascia
So decide on security at design stage. If your insurer asks for a level of protection, say so early: laminated glass, a frame fixed back to the structure and an internal grille may meet it without an external shutter. Policies differ between boroughs, so check your own council's guidance.
Shopfronts in conservation areas and on listed buildings
In a conservation area the council must pay special attention to preserving or enhancing the character or appearance of the area, so a new shopfront is looked at closely. Expect it to want surviving traditional elements, such as pilasters, fascia, cornice and stallriser, kept or reinstated. Illuminated signs there always need express advertisement consent.
On a listed building, listed building consent is needed for any alteration that would affect its character as a building of special architectural or historic interest, and doing such work without consent is a criminal offence. That can cover the shopfront, signs and shutters, alongside planning permission and advertisement consent. For historic buildings, Approved Document M asks for access to be improved as far as practically possible without harming their character, with advice from the council's conservation and access officers.
Which Building Regulations apply to a new shopfront?
Planning permission and Building Regulations are separate, and a shopfront usually needs both. Approved Document K explains that replacing a whole unit, frame and glass together, is building work, while reglazing an existing frame as a repair is not. Replacement windows and doors in a non-domestic building can be self-certified by an installer registered with a competent person scheme for that work (excluding structural glass, curtain walling and revolving doors); otherwise the work goes through building control. Where the entrance is altered, the work is likely to be a material alteration under regulation 3, which brings in Part M and the escape requirements of Part B: Approved Document M says altered entrances must comply with requirement M1.
Part M: access through the shop front door
Approved Document M Volume 2 covers access to buildings other than dwellings, and the Equality Act 2010 places separate duties on service providers. The figures that shape a shop front door are:
- Clear width (Table 2): at least 1,000 mm for external doors to buildings used by the general public in a new building, 775 mm in an existing one, measured past the door stop and any projecting handle, so the leaf must be wider; with double doors it applies to one leaf
- Threshold (para 2.7): level, or no more than 15 mm high in total, with any upstand over 5 mm chamfered or rounded, and a level landing 1,500 by 1,500 mm outside
- Opening force (para 2.17): no more than 30 N at the leading edge to 30° open and 22.5 N from 30° to 60°, with 300 mm clear on the pull side beside the leading edge and a lever handle usable with a closed fist
- Powered doors (paras 2.10 and 2.21): the most satisfactory solution for most people, with automatic sliding doors avoiding the risks of automatic swing doors; they should revert to manual or fail safe open if the power fails
A closer strong enough to shut a heavy glazed door against the wind can make it too hard to open, which is why busy shops often choose an automatic sliding door. See our commercial aluminium doors, and the types of commercial doors guide for door sizes, hardware and escape rules.
Part K: safety glass and manifestation in shopfronts
Approved Document K treats three zones as critical locations: glazing in a door within 1,500 mm of the floor, in a side panel within 300 mm of either edge of the door (up to 1,500 mm), and in walls and screens within 800 mm of the floor. In a shopfront that is the door, the panels beside it and the lower display glass. Glass there should break safely, be robust, be in small panes or be protected; in practice that means toughened or laminated glass to Class 3 of BS EN 12600 (Class 2 in a door or side panel where the pane is wider than 900 mm).
Shops are named in the guidance on manifestation: large uninterrupted areas of transparent glazing in shops and showrooms are critical locations, because people may walk into them. Glass doors and screens need manifestation at 850 to 1,000 mm and 1,400 to 1,600 mm above the floor, contrasting with the background, as a logo or sign at least 150 mm high or bands at least 50 mm high, and a glass door in a glazed screen needs a high-contrast strip at the top and both sides. The shop logo can do this job if it is planned in at the right heights. Part K is under review: the Building Safety Regulator's call for evidence closes on 11 January 2027, and the current 2013 edition stays in place while the review runs. Any changes would be consulted on first.
Part L: U-values for display glass and the shop door
Approved Document L Volume 2 says a replaced window or door unit in a non-domestic building should be draught-proofed and meet the limiting U-values in its Table 4.1. For a shopfront:
- Display windows: no maximum U-value. Approved Document L defines a display window as glazing, including glazed doors, that displays products or services to the public at the edge of the building, at an access level, next to a pedestrian thoroughfare; glazing more than 3 m above the access level or with a permanent workspace behind it does not normally count
- Doors: 1.6 W/m²K for pedestrian doors, including glazed doors, or 3.0 W/m²K for a high-usage entrance door, an entrance many people move through, with automatic closers and, where possible, a lobby
- Other windows in the frontage, such as office or upper-level glazing: 1.6 W/m²K
The 2026 edition, which takes effect on 24 March 2027, keeps the same figures and the display window exemption. Whether a glazed shop door counts as display glazing or as a pedestrian door is for building control to confirm, so settle it before the door is ordered.
Part B: when the shop door is also the fire exit
In many shops the front door is also the final exit. Approved Document B Volume 2 says that in shops, doors on escape routes from rooms with more than 60 people should have no locks, latches or bolts, or panic fastenings to BS EN 1125; escape doors should open by at least 90°, and in the direction of escape where more than 60 people might use them in a fire; and automatic doors across an escape route should fail safe open or have a manual swing door of the required width beside them. Security locks used only when the building is empty can be acceptable with proper management procedures.
Watch the pavement: section 153 of the Highways Act 1980 says a door onto a street should not open outwards (unless, on a public building, the council and highway authority consent), and the council can require one that does to be altered. If the fire strategy needs an outward-opening exit, a recessed entrance or an automatic sliding door that fails safe open are options to agree with building control early.
Shopfront security: PAS 24, LPS 1175 and laminated glass
The Building Regulations do not set a security standard for shopfronts: Approved Document Q applies to new dwellings only. Security is set by the insurer, the landlord or the specification, usually by reference to one of these:
- PAS 24: the BSI specification for doorsets and windows that resist casual or opportunistic burglary, for dwellings and other buildings at comparable risk; often used as a benchmark on commercial projects
- LPS 1175: the Loss Prevention Certification Board standard for intruder-resistant building components, maintained by BRE; Issue 8 rates products by a tool category (A to H) and a delay time in minutes, replacing the older SR1 to SR8 ratings
- BS EN 1627: European burglar resistance classes RC1 to RC6 for doorsets, windows, curtain walling, grilles and shutters
- Laminated glass: the interlayer holds broken glass together, so a broken pane still helps keep the opening closed until it is replaced
A rating applies only to the tested configuration of frame, glass, locks and fixings, so ask for the certificate for the exact door or shutter supplied and check it against what your insurer asked for.
Shopfront quote checklist: what to send
A shopfront is made to measure, so the more of this you can send, the faster and more accurate the price. Rough measurements and photos are enough to start; a survey confirms the sizes before anything is made.
- The address, and whether the building is listed or in a conservation area
- Opening width and height, from pavement to the underside of the fascia, and any pilasters that stay
- Photos of the whole frontage from across the street, and close-ups of the head, sill and threshold
- The door: single, double, automatic sliding, bifold or pivot, which way it opens, and whether it is the fire exit
- Footfall and opening hours, so the hinges, closer or operator suit the use
- The glass: security, acoustic or solar control needs, and what your insurer asks for
- The signage zone: fascia depth and whether the sign will be lit
- Stallriser, transom or vents, and the frame colour (RAL number if known)
- Planning status: drawings, pre-application advice or conditions
- Access and timing: loading restrictions, whether the shop keeps trading, and when it must be secure each night
BDF Architectural designs, makes and installs aluminium shopfronts and shop front doors across London and the South East, fabricated to measure in West Drayton on Schüco, Cortizo and Aluprof systems, in any RAL colour, with toughened or laminated safety glass. We draw the frontage early so the drawings can go with the planning application. Restaurants and bars that trade with the front open can use commercial bifold doors, as we fitted across the ground-floor commercial units at Blackfriars in the City of London.
Frequently asked questions
Do I need planning permission to replace a shop front?
Usually, yes. Works that materially affect the external appearance of a building need planning permission, and a new shopfront normally does; permitted development rights for shops specifically exclude a new shop front and the alteration or replacement of an existing one. Routine maintenance, such as reglazing the existing frame or repainting in the same colour, usually does not. For an application that is not major development, the council has 8 weeks to decide.
Do roller shutters on a shop need planning permission?
External shutters and grilles do: installing or replacing a security grille or shutter on a shop front is excluded from permitted development. Councils such as Brent resist solid shutters and prefer laminated glass or an internal open-type grille behind the glass, which may not need planning permission, although on a listed building it will need listed building consent.
Does a shop sign need advertisement consent?
Outside signs need consent, but many non-illuminated fascia and hanging signs have deemed consent under Class 5 of Schedule 3 to the Advertisement Regulations 2007, as long as they refer only to the business, sit on a wall with a shop window, are no higher than 4.6 m or the bottom of any first-floor window, and use characters no more than 0.75 m high. Signs outside those limits need express consent from the council.
Can I have an illuminated shop sign in a conservation area?
Only with express advertisement consent. The deemed consent class for illuminated signs on business premises, Class 4B, does not apply in conservation areas, National Parks, Areas of Outstanding Natural Beauty or the Broads, so you need to apply to the council, which will judge the design against its conservation area and shopfront guidance.
Does a new shopfront need Building Regulations approval?
Yes. Replacing a whole window or door unit, frame and glass, is building work. An installer registered with a competent person scheme for replacement windows and doors in non-domestic buildings can self-certify it; otherwise it goes through building control. Where the entrance is altered, Part M access and the Part B escape requirements also apply.
How wide does a shop front door need to be?
Approved Document M Volume 2 recommends a minimum effective clear width of 1,000 mm for external doors to buildings used by the general public in new buildings, and 775 mm in existing buildings. The clear width is measured past the door stop and any projecting handle, so the leaf must be wider, and with double doors the width applies to one leaf.
Does shopfront glass have to be safety glass?
In the critical locations set out in Approved Document K it does: glazing in a door within 1,500 mm of the floor, in side panels within 300 mm of the door, and in walls and screens within 800 mm of the floor. In practice that means toughened or laminated glass. Large panes in shops also need manifestation at 850 to 1,000 mm and 1,400 to 1,600 mm above the floor.
Do shopfronts have to meet U-value requirements?
Approved Document L Volume 2 sets no maximum U-value for display windows and similar glazing, although in a new building their effect counts in the energy calculation. Doors have limits: 1.6 W/m²K for pedestrian doors, or 3.0 W/m²K for high-usage entrance doors with automatic closers. Building control confirms which category a glazed shop door falls into.
Sources and further reading
- Town and Country Planning Act 1990, section 55: meaning of development (legislation.gov.uk)
- General Permitted Development Order 2015, Schedule 2, Part 7 (legislation.gov.uk)
- Control of Advertisements Regulations 2007, Schedule 3: deemed consent (legislation.gov.uk)
- Outdoor advertisements and signs: a guide for advertisers (GOV.UK)
- Shop advert, fascia or projecting sign (Planning Portal)
- Planning (Listed Buildings and Conservation Areas) Act 1990, section 7 (legislation.gov.uk)
- Brent Council, Shopfronts SPD3, June 2018
- Royal Borough of Kensington and Chelsea, Shopfront Design Guidelines SPD
- Royal Borough of Kingston upon Thames, Shopfront and Shopsign Design Guide SPD
- Approved Document M: access to and use of buildings (GOV.UK)
- Approved Document K: protection from falling, collision and impact (GOV.UK)
- Approved Document L: conservation of fuel and power (GOV.UK)
- Approved Document B: fire safety (GOV.UK)
- Building Regulations 2010, Schedule 3: self-certification schemes (legislation.gov.uk)
- Highways Act 1980, section 153: doors opening onto a street (legislation.gov.uk)
- Have your say on the future of Part K (GOV.UK)